Skip to main content

Risk of root damage after using lateral cephalogram and intraoral scan for guided insertion of palatal miniscrews

Abstract

Background

Guided insertion of palatal miniscrews using a lateral cephalogram instead of cone beam computed tomography (CBCT) significantly reduces the radiation level for the patient. Till now no data are available on the risk of hitting the incisors in this regard, which is one of the worst clinical complications when inserting a paramedian miniscrew. Hence, this study aims to investigate the distance between the mini-implant and the roots of the central and lateral incisors.

Methods

Lateral cephalogram, an intraoral scan, and CBCT of 20 patients were superimposed. After a miniscrew (1.7 × 8 mm) placement based on intraoral scan and lateral cephalogram, the CBCT was used as control for the distance between the miniscrews and the roots of the incisors.

Results

The mean value of the shortest distance between the miniscrew and roots of the incisors in the lateral cephalogram was 4.74 ± 1.67 mm. The distance between both miniscrews and the central incisors measured in the CBCT was 5.03 ± 2.22 mm and 5.26 ± 2.21 mm and between the two miniscrews and the lateral incisors was 4.93 ± 1.91 mm and 5.21 ± 2.64 mm. No significant differences between the distances in the CBCT and the lateral cephalogram could be observed. In one case, the CBCT control revealed the penetration of two palatally displaced canines after insertion based on intraoral scan and lateral cephalogram.

Conclusions

The use of an intraoral scan and a lateral cephalogram for guided paramedian insertion of palatal miniscrews can prevent incisor root damage. This may reduce the radiation since no CBCT seems necessary. The current investigation focuses on the anterior paramedian area of the palate. Outside that region and in complex cases with displaced teeth in the palatal area, a CBCT might be indicated.

Peer Review reports

Background

Over the past two decades, various approaches for skeletal anchorage have been developed [1, 2, 3]. Within this group, orthodontic mini-implants have become the most common variant [1, 4, 5, 6]. They have proven to reinforce orthodontic anchorage in clinical practice [7, 8] and have opened up new treatment options [9, 10]. The literature shows that the success rates are encouraging [11, 12, 13]. In particular, the anterior palate has been established as the insertion region because of its good bone supply [14, 15]. Taking a closer look, the ideal spot can be found within a T-shaped area, anterior paramedian, and median along the suture [16]. Studies have shown high stability after insertion in this area, with no statistical differences for median and paramedian implants [17, 18]. The paramedian area can be used for nearly all indications, including skeletal borne rapid palatal expansion (RPE), hence it is preferred by most clinicians [10, 19]. The best clinical guideline to identify the paramedian area of the T-Zone appears to be the third palatal ruga, whereas dental landmarks are not reliable due to possible tooth migration [20]. One drawback of paramedian insertion compared to median placement is its closer proximity to the incisor roots. On one hand, the distance to the dental roots is correlated with the success rate of mini-implants [21, 22] and on the other hand, there is a risk of root damage. The superficial lesion seemed to heal with the cementum [23]. When the mini-implant hits the apex of the tooth, the bundle of nerves and blood vessels can be cut, and root canal treatment must be performed [24]. For precise and safe insertion of dental implants, the use of a surgical guide was introduced a long time ago [25]. Currently, it is well established, mostly based on CBCT data, and its accuracy has been underlined in current investigations [26]. Orthodontic mini-implants are mostly inserted without guidance. However, a paper published in 2009 by Cousley introduced a surgical guide for mini-implant insertions [27]. Maino et al. were the first to superimpose a lateral cephalogram with an intraoral scan of the maxilla for mini-implant planning [28]. Kim et al. measured the bone height at the anterior palate on the CBCT median and stepwise to the sides, and compared it with the bone height measured on the lateral cephalogram [29]. They found that the bone height seen on the lateral cephalogram matched the bone height 5 mm paramedian on CBCT. Between the 5 mm paramedian and suture, the bone height was even higher. Since the lateral cephalogram underestimates the paramedian bone supply close to the midline, it seems suitable to use the superimposition of intraoral scan and lateral cephalogram for paramedian-guided insertion within 5 mm from the midline. This would make CBCT superfluous in these cases, leading to a significant reduction in the radiation dose for patients. The results of the first study support the applicability of this protocol with regard to bone support [30]. There are no data available on the risk of hitting the incisors in this regard, which is one of the worst clinical complications when inserting a paramedian miniscrew. Hence, this study aims to investigate the distance between the mini-implant and the roots of the central and lateral incisors. The risk of root damage after using lateral cephalograms and intraoral scans for the guided insertion of palatal miniscrews should be evaluated.

Methods

The patient database of a private practice in Traben-Trarbach, Germany, was screened. The inclusion criteria were initial diagnostics containing a lateral cephalogram, an intraoral scan, and CBCT. Since, CBCT is not a standard diagnostic tool in orthodontics, in most cases, it was performed with a certain time lag to elucidate special findings. For inclusion in this study, the maximum time period between the scan, lateral cephalogram, and CBCT was set to 2 weeks. The exclusion criteria were cleft and impacted upper incisors.

For each patient, the lateral cephalogram, intraoral scan of the maxilla, and CBCT were superimposed using OnyxCeph3™® software (image instruments, Chemnitz, Germany) (Fig. 1). Incisal edges of the central incisors and the buccal cusp tips of the molars were used for matching in the YZ-plane. To superimpose 2D and 3D data according to the XY-plane, a specially developed algorithm was used [31].

Fig. 1
figure 1

Data set after three-dimensional superimposition of lateral cephalogram, intraoral scan of the maxilla, and CBCT

First, the intraoral scan of the maxilla was selected and two mini-implants (1.7 × 8 mm, Orthoeasy, Forestadent, Germany) were inserted at the anterior palate, according to clinical guidelines, directly behind the third palatal rugae and 3 mm paramedian (Fig. 2a). Subsequently, the matched lateral cephalogram was displayed, and the implant position was optimised according to the bone supply and distance to the incisor roots (Fig. 2b). After that, the CBCT was displayed as reference, and the shortest distance between each mini-implant and the respective lateral and central incisors was measured using OnyxCeph3™® software (Fig. 2c). These values were compared to each other and to the shortest distance between the mini-implant and the incisors on the lateral cephalogram.

Fig. 2
figure 2

Sequence of insertion and measurements. Placement according to clinical guidelines (a) correction of position and angle using the lateral cephalogram, followed by measurement of the distance between miniscrews and incisors (b) application of the CBCT for measurement of the distances between both implants and central and lateral incisors

All data were tested for normal distribution using the Shapiro-Wilk test. All measurements were taken twice by a second investigator to evaluate the reproducibility of distance measurements. Paired t-tests (p < 0.05) were used to compare measurements. All distances were tested for statistical differences using ANOVA. For an additional assessment of the setting value, 95% confidence intervals were calculated. Descriptive statistics were used to examine single values of special interest.

Results

Twenty patients were included in the study after applying inclusion and exclusion criteria. The group consisted of nine female and 11 male patients. The mean age was 13.95 ± 3.40 years. Since the Shapiro-Wilk test revealed a normal distribution of the data, parametric tests were applied.

The paired t-tests showed no statistical significance between the first and repeated measurements; p-values ranged from 0.193 to 0.821.

ANOVA showed no differences (p < 0.05) in the distances between the incisors and implants in the lateral cephalograms and CBCT images (Table 1). The mean values even showed a shorter distance measured in the lateral cephalogram than that measured for each incisor using CBCT. However, these differences were not statistically significant. The extensive overlap of all confidence intervals underlines the value of the chosen settings of the study design.

Table 1 Distances between miniscrews and roots measured in the lateral cephalogram and in the CBCT

Looking at the descriptive data, the minimum distance measured in each group was slightly smaller than the distances measured using CBCT. The shortest distance was found between the right temporary anchorage device (TAD) and right central incisor (0.2 mm).

In one case, the evaluation of the implant position using CBCT revealed the penetration of two palatally impacted canines.

Discussion

The anterior palate, especially the paramedian area, has become one of the most favoured sites for mini-implant insertion [18, 32]. To make insertions more secure and to enable insertion of implants and appliances in one visit, guided mini-implant insertion is becoming increasingly popular [33]. The replacement of CBCT with a lateral cephalogram for 3D planning of paramedian mini-implants would lead to a significant reduction in the radiation dose for the patient. A lateral cephalogram is normally taken when planning a case; therefore, no extra X-ray would be needed for implant planning. This seems to be sufficient for the evaluation of bone support [29, 30]. The distance to the roots correlates with the success rate of the mini-implants [21]. Moreover, since severe damage to an incisor root is a realistic scenario [24] this method should be investigated in this regard. This was the aim of this study.

On the lateral cephalogram, there was a superimposition of all four incisors in one layer. Owing to the 2-dimesional recording technique, not all roots can be seen clearly. After using the combination of intraoral scan and lateral cephalogram for implant insertion, the real distances of each implant to the respective central and lateral incisors in CBCT were measured three-dimensionally as a control.

For this purpose, a group of patients was collected for whom an intraoral scan, lateral cephalogram, and CBCT were available. According to the inclusion criteria, CBCT was performed not later than 2 weeks after the basic diagnosis to ensure that no changes occurred. The software used for superimposition and measurements has already been proven to be applicable to other investigations [34]. The method for superimposing the two-dimensional lateral cephalogram and the three-dimensional data, according to the XY-plane was subject to a critical investigation [31]. The reproducibility of the measurements was proven by the repeated performance, which showed no significant differences for all measurements. For the clinical relevance of this study it is crutial, that the virtually planned position of the TAD is achievable with clinical precision. This was affirmed by an investigation of Iodice et al. [35].

Considering the mean values and standard deviations, the results showed safe distances to the roots in all groups. There were no statistically significant differences between the distances measured in the lateral cephalogram and those measured using CBCT in all groups. The extensive overlap of all 95%confidence intervals underlines the value of the chosen settings of the study, indicating a sufficient number of cases. The distances seen in the lateral cephalogram even underestimated the “real” distances in the CBCT. These findings underline the applicability of a combination of intraoral scans and lateral cephalograms. Using CBCT as a control, no incisor root was hit by the implant. Taking a closer look at the minimum distances found in each group, the values were slightly smaller in the CBCT groups, but did not go below 1 mm, with one exception. A single root showed a distance of 0.2 mm. In addition to the fact that this might affect the survival of mini-implants [21] it might also lead to minor damage to the root. Maino et al. intentionally moved bicuspids towards mini-implants and reported that minor resorptions in some cases already occurred at a distance of 0.6 mm [36]. However, these small lesions healed with cementum. Moreover, attention should be paid to the fact that in one case, the palatally impacted canines were hit by mini-implants when evaluating their position on CBCT.

Overall, the results of this study indicate that the use of an intraoral scan and a lateral cephalogram for guided paramedian insertion of mini-implants can prevent incisor root damage. No potential damages of the incisal roots were observed. The distance in the lateral cephalogram underestimated the real distances on average. However, a safe distance should be maintained because avoidance of very close proximity is not ensured in every single case. It should also be mentioned, that this protocol is strictly limited to the anterior palate within the T-Zone. CBCT should be performed outside this area and in complex cases of displaced canines.

Conclusions

Based on the results of this investigation it can be concluded that the use of an intraoral scan and a lateral cephalogram for guided paramedian insertion of mini-implants can prevent incisor root damage. There were no statistical differences between the distances between the implant and the roots seen in the cephalogram and all groups of CBCT images. A safety distance should be maintained to avoid a close proximity in single cases. The current investigation focuses on the anterior paramedian area of the palate. Outside that region and in complex cases with displaced teeth in the palatal area, a CBCT might be indicated.

Availability of data and materials

The datasets used and/or analysed during the current study are available from the corresponding author on reasonable request.

Abbreviations

CBCT:

Cone beam computed tomography

RPE:

Rapid palatal expansion

TAD:

Temporary anchorage device

References

  1. Kanomi R. Mini-implant for orthodontic anchorage. J Clin Orthod. 1997;31(11):763–7.

    PubMed  CAS  Google Scholar 

  2. De Clerck H, Geerinckx V, Siciliano S. The Zygoma Anchorage system. J Clin Orthod. 2002;36(8):455–9.

    PubMed  Google Scholar 

  3. Seo KW, Nahm KY, Kim SH, Chung KR, Nelson G. Chin plate with a detachable C-tube head serves for both osteotomy fixation and orthodontic anchorage. J Craniofac Surg. 2013;24(4):424–8.

    Article  Google Scholar 

  4. Costa A, Raffainl M, Melsen B. Miniscrews as orthodontic anchorage: a preliminary report. Int J Adult Orthodon Orthognath Surg. 1998;13(3):201–9.

    PubMed  CAS  Google Scholar 

  5. Melsen B, Costa A. Immediate loading of implants used for orthodontic anchorage. Clin Orthod Res. 2000;3(1):23–8.

    Article  CAS  Google Scholar 

  6. Wilmes B. Fields of application of mini-implants. London: Quintessence; 2008.

    Google Scholar 

  7. Yao CC, Lai EH, Chang JZ, Chen I, Chen YJ. Comparison of treatment outcomes between skeletal anchorage and extraoral anchorage in adults with maxillary dentoalveolar protrusion. Am J Orthod Dentofac Orthop. 2008;134(5):615–24.

    Article  Google Scholar 

  8. Upadhyay M, Yadav S, Patil S. Mini-implant anchorage for en-masse retraction of maxillary anterior teeth: a clinical cephalometric study. Am J Orthod Dentofac Orthop. 2008;134(6):803–10.

    Article  Google Scholar 

  9. Wilmes B, Drescher D. Vertical periodontal ligament distraction--a new method for aligning ankylosed and displaced canines. J Orofac Orthop. 2009;70(3):213–23.

    Article  Google Scholar 

  10. Wilmes B, Nienkemper M, Drescher D. Application and effectiveness of a mini-implant- and tooth-borne rapid palatal expansion device: the hybrid hyrax. World J Orthod. 2010;11(4):323–30.

    PubMed  Google Scholar 

  11. Papageorgiou SN, Zogakis IP, Papadopoulos MA. Failure rates and associated risk factors of orthodontic miniscrew implants: a meta-analysis. Am J Orthod Dentofac Orthop. 2012;142(5):577–95 e7.

    Article  Google Scholar 

  12. Schätzle M, Mannchen R, Zwahlen M, Lang NP. Survival and failure rates of orthodontic temporary anchorage devices: a systematic review. Clin Oral Implants Res. 2009;20(12):1351–9.

    Article  Google Scholar 

  13. Crismani AG, Bertl MH, Celar AG, Bantleon HP, Burstone CJ. Miniscrews in orthodontic treatment: review and analysis of published clinical trials. Am J Orthod Dentofac Orthop. 2010;137(1):108–13.

    Article  Google Scholar 

  14. Kang S, Lee SJ, Ahn SJ, Heo MS, Kim TW. Bone thickness of the palate for orthodontic mini-implant anchorage in adults. Am J Orthod Dentofac Orthop. 2007;131(4 Suppl):S74–81.

    Article  Google Scholar 

  15. Triaca A, Antonini M, Wintermantel. Ein neues Titanflachschrauben-Implantat zur orthodontischen Verankerung am anterioren Gaumen. Inf Orthod Kieferorthop. 1992;24:251–7.

    Google Scholar 

  16. Wilmes B, Ludwig B, Vasudavan S, Nienkemper M, Drescher D. The T-zone: median vs. Paramedian Insertion of Palatal Mini-Implants. J Clin Orthod. 2016;50(9):543–51.

    PubMed  Google Scholar 

  17. Nienkemper M, Wilmes B, Pauls A, Drescher D. Mini-implant stability at the initial healing period: a clinical pilot study. Angle Orthod. 2014;84(1):127–33.

    Article  Google Scholar 

  18. Nienkemper M, Pauls A, Ludwig B, Drescher D. Stability of paramedian inserted palatal mini-implants at the initial healing period: a controlled clinical study. Clin Oral Implants Res. 2015;26(8):870–5.

    Article  Google Scholar 

  19. Ludwig B, Glasl B, Zorkun B, Wilmes B, Kinzinger G, Lisson J. Forcierte Gaumennahterweiterung mit skelettalem Kraftansatz: Die Hybrid-GNE. Kieferorthop. 2009;23(4):267–74.

    Google Scholar 

  20. Hourfar J, Kanavakis G, Bister D, Schatzle M, Awad L, Nienkemper M, et al. Three dimensional anatomical exploration of the anterior hard palate at the level of the third ruga for the placement of mini-implants--a cone-beam CT study. Eur J Orthod. 2015;37(6):589–95.

    Article  Google Scholar 

  21. Kuroda S, Yamada K, Deguchi T, Hashimoto T, Kyung HM, Takano-Yamamoto T. Root proximity is a major factor for screw failure in orthodontic anchorage. Am J Orthod Dentofac Orthop. 2007;131(4):68–73.

    Article  Google Scholar 

  22. Chen YH, Chang HH, Chen YJ, Lee D, Chiang HH, Yao CC. Root contact during insertion of miniscrews for orthodontic anchorage increases the failure rate: an animal study. Clin Oral Implants Res. 2008;19(1):99–106.

    PubMed  CAS  Google Scholar 

  23. Kadioglu O, Buyukyilmaz T, Zachrisson BU, Maino BG. Contact damage to root surfaces of premolars touching miniscrews during orthodontic treatment. Am J Orthod Dentofac Orthop. 2008;134(3):353–60.

    Article  Google Scholar 

  24. Er K, Bayram M, Tasdemir T. Root canal treatment of a periradicular lesion caused by unintentional root damage after orthodontic miniscrew placement: a case report. Int Endod J. 2011;44(12):1170–5.

    Article  CAS  Google Scholar 

  25. Federick DR, Rey MD. A surgical guide for insertion of implant fixtures. Implant Dent. 1992;1(2):129–31.

    Article  CAS  Google Scholar 

  26. Ku JK, Lee J, Lee HJ, Yun PY, Kim YK. Accuracy of dental implant placement with computer-guided surgery: a retrospective cohort study. BMC Oral Health. 2022;22(1):8.

    Article  Google Scholar 

  27. Cousley RR. A stent-guided mini-implant system. J Clin Orthod. 2009;43(6):403–7.

    PubMed  Google Scholar 

  28. Maino BG, Paoletto E, Lombardo L, Siciliani G. A three-dimensional digital insertion guide for palatal Miniscrew placement. J Clin Orthod. 2016;50(1):12–22.

    PubMed  Google Scholar 

  29. Kim YJ, Lim SH, Gang SN. Comparison of cephalometric measurements and cone-beam computed tomography-based measurements of palatal bone thickness. Am J Orthod Dentofac Orthop. 2014;145(2):165–72.

    Article  Google Scholar 

  30. Möhlhenrich SC, Brandt M, Kniha K, Bock A, Prescher A, Hölzle F, et al. Suitability of virtual plaster models superimposed with the lateral cephalogram for guided paramedian orthodontic mini-implant placement with regard to the bone support. J Orofac Orthop. 2020;81(5):340–9.

    Article  Google Scholar 

  31. Sauppe S, Abkai C, Hourfar J, Ludwig B, Ulrici J, Hell E. Automatic fusion of lateral cephalograms and digital volume tomography data-perspective for combining two modalities in the future. Dentomaxillofac Radiol. 2015;44(9):20150073.

    Article  CAS  Google Scholar 

  32. Ludwig B, Zachrisson BU, Rosa M. Non-compliance space closure in patients with missing lateral incisors. J Clin Orthod. 2013;47(3):180–7.

    PubMed  Google Scholar 

  33. Maino BG, Paoletto E, Lombardo L, Siciiani G. From planning to delivery of a bone-borne rapid maxillary expander in one visit. J Clin Orthod. 2017;51(4):198–207.

    PubMed  Google Scholar 

  34. Legal S, Moralis A, Waiss W, Zeman F, Winkler C, Müller S, et al. Accuracy in orthognathic surgery─comparison of preoperative plan and postoperative outcome using computer-assisted two-dimensional cephalometry by the Onyx Ceph ® system. J Craniomaxillofac Surg. 2018;46(10):1793–9.

    Article  Google Scholar 

  35. Iodice G, Nanda R, Drago S, Repetto L, Tonoli G, Silvestrini-Biavati A, et al. Accuracy of direct insertion of TADs in the anterior palate with respect to a 3D-assisted digital insertion virtual planning. Orthod Craniofacial Res. 2022;25(2):192–8. https://doi.org/10.1111/ocr.12525 Epub 2021 Aug 9.

    Article  Google Scholar 

  36. Maino BG, Weiland F, Attanasi A, Zachrisson BU, Buyukyilmaz T. Root damage and repair after contact with miniscrews. J Clin Orthod. 2007;41(12):762–6 quiz 50.

    PubMed  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

Open Access funding enabled and organized by Projekt DEAL. The authors declare that there was no source of funding.

Author information

Authors and Affiliations

Authors

Contributions

MN and BL have set up the study idea and design. BL performed the measurements and superimpositions. MN analysed the data and wrote the paper. BL created the figures. The author(s) read and approved the final manuscript.

Corresponding author

Correspondence to Manuel Nienkemper.

Ethics declarations

Ethics approval and consent to participate

Not applicable for this retrospective investigation of anonymised data.

Consent for publication

Consent was obtained from patients or parents.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Nienkemper, M., Ludwig, B. Risk of root damage after using lateral cephalogram and intraoral scan for guided insertion of palatal miniscrews. Head Face Med 18, 30 (2022). https://doi.org/10.1186/s13005-022-00335-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13005-022-00335-0

Keywords