Assessing degradation of composite resin cements during artificial aging by Martens hardness

Abstract

Background

Aim of the study was to verify the efficiency of Martens hardness measurements in detecting the degradation of composite resin cements during artificial aging.

Methods

Four cements were used: Variolink II (VL2), RelyX Unicem 2 Automix (RUN), PermaFlo DC (PDC), and DuoCem (DCM). Specimens for Martens hardness measurements were light-cured and stored in water at 37 °C for 1 day to allow complete polymerization (baseline). Subsequently the specimens were artificially aged by water storage at 37 °C or thermal cycling (n = 6). Hardness was measured at baseline as well as after 1, 4, 9 and 16 days of aging. Specimens for indirect tensile strength measurements were produced in a similar manner. Indirect tensile strength was measured at baseline and after 16 days of aging (n = 10). The results were statistically analyzed using one-way ANOVA (α = 0.05).

Results

After water storage for 16 days hardness was significantly reduced for VL2, RUN and DCM while hardness of PDC as well as indirect tensile strength of all cements were not significantly affected. Thermal cycling significantly reduced both, hardness and indirect tensile strength for all cements. No general correlation was found between Martens hardness and indirect tensile strength. However, when each material was analyzed separately, relative change of hardness and of indirect tensile strength revealed a strong linear correlation.

Conclusions

Martens hardness is a sensible test method to assess aging of resin composite cements during thermal cycling that is easy to perform.

Peer Review reports

Background

Advances in CAD/CAM technology have increased the application of all-ceramic restorations in dentistry [1, 2]. In clinical use, ceramic has proven to be a reliable restorative material showing survival rates of up to 93% after 10 years [3,4,5,6,7,8]. Ceramic materials provide high aesthetic options but they are susceptible to tensile stress, which implies a higher risk of failures during functional loading, such as veneer chipping or fractures [9,10,11]. To prevent any tensile stress in the ceramic, the restoration should not exhibit mechanical retention on the prepared tooth [12]. Therefore, a stable adhesive cementation is decisive for the long term success of ceramic restorations [13]. Further, it has been shown that the strength of ceramic restorations is doubled when adhesively cemented, because the intaglio surface of the restoration is shielded from tensile stress [14].

Adhesive cementation is technique-sensitive and requires several steps. The hydrophilic tooth surface must be conditioned in order to remove the smear layer and to create a micro-structured surface. In a second step the tooth surface must be primed in order to make it wettable to a hydrophobic resin composite cement. Priming is accomplished by bifunctional monomers in the primer such as HEMA, which are applied at first and bind to the tooth substance with a hydrophilic end while the hydrophobic end contains a polymerizable group that can bind to the resin composite cement [15].

Efforts were made to simplify the process of surface conditioning for adhesive cementation [16]. Therefore, besides the traditional "etch and rinse" systems, which require all steps of surface treatment, self-adhesive cements were developed, comprising monomers with phosphate groups, which are able to chemically bond to the tooth substance.

In the oral cavity restorations are subjected to mechanical, chemical and thermal stress and thus undergo a process of aging. To simulate the effect of the humid environment in the oral cavity by laboratory testing, storage in water or artificial saliva at 37 °C may be performed. To simulate the effect of temperature changes in the oral cavity, thermal cycling is usually applied [17,18,19,20]. Specimens are in turn immersed in water of 5 °C and 55 °C, simulating extreme situations with exposure to ice cream and hot beverages.

To analyze the effect of aging, specimens for flexural strength test can be used [21]. But the preparation of these specimens is time consuming and complex. An alternative is to use the indirect tensile strength test [22,23,24,25]. In contrast to flexural specimens the preparation of indirect tensile specimens is less complex. However, as any chemical stress on restorative materials generated in the oral cavity particularly affects the superficial layers of the respective material, assessment of aging effects might also be achieved by hardness measurement, which is a very easily performed test. The only requirement is an even and smooth surface of the specimen. A further advantage of hardness measurements is that multiple measurements can be performed on one specimen, thus alterations over time can be followed.

Published results investigating correlations between strength and hardness of resin composite materials are not consistent. In various studies it has been demonstrated that hardness of composite filling materials is not affected by thermal cycling, while flexural strength decreases significantly under the same conditions [26,27,28,29]. In contrast to these findings Medeiros et al. [24] report on a positive correlation between Vickers hardness and indirect tensile strength when investigating the aging of a composite resin restorative material, while Aguiar et al. [25] observed the opposite. However, they both used micro-hardness, which measures only the most superficial layer of the specimens and all measurements were performed after only 24 h water storage. Further, it is unknown whether these observations also apply for resin composite cements.

In all studies Vickers hardness was used. Compared to other hardness test methods, Martens hardness has the advantage that not only plastic but also elastic deformation is measured, which is closer to flexural or indirect tensile strength measurements. Hence, the aim of this study was to analyze the efficiency of Martens hardness measurements in assessing the effect of artificial aging on resin composite cements. Previous investigations with one cement have shown that 16 days of aging by water storage or thermal cycling are sufficient to detect aging effects [23]. Therefore, hardness measurements were performed after water storage at 37 °C or thermal cycling up to 16 days. Indirect tensile strength tests before aging and after 16 days of aging were conducted for the reason of comparison.

Methods

Cements

Four different resin composite cements were used in this study, three conventional multi-step materials and one self-adhesive cement (Table 1).

Table 1 Summary of cements used

Specimen preparation for Martens hardness measurements

To measure Martens hardness, specimens with dimensions of 25.0 × 2.0 × 2.0 mm were produced in sets of 6 as described in ISO 4049. The cements were mixed according to the manufacturer’s instructions and filled into cavities of a customized Teflon mold. Glass slabs 1 mm in thickness and covered with a transparent Mylar foil (Hawe Transparent Strips, KerrHawe, Bioggio, Switzerland) were placed on both sides of the mold to keep the cement in place.

Light-curing was performed with a polymerization lamp (Elipar, 3 M ESPE, Seefeld, Germany) providing an intensity of 1200 mW/cm2. The exit window of the light-curing device had a diameter of 8 mm. It was positioned directly on the glass slab, which means in a well-defined distance of 1 mm to the specimen’s surface. Light-curing was started in the center of the specimen. After light exposure the exit window was moved to the section next to the center overlapping the previous section by half the diameter of the exit window (i.e. 4 mm). The procedure was reiterated until the specimen on the one side of the center had been completely exposed to the light. Thereafter the section on the other side of the center was light-cured in the same manner. The whole procedure was repeated from the rear side of the specimen. Duration of each light exposure was 10 s (PDF, RUN, and VL2) or 20 s (DCM) according to the manufacturers’ instructions.

Specimen preparation for indirect tensile strength tests

To measure indirect tensile strength, cylindrical test specimens (3 mm in height and 3 mm in diameter) were produced in sets of 10 using a customized Teflon mold. The cements were mixed according to the manufacturer’s instructions and filled into the cavities of the Teflon mold. A glass slab covered with a transparent Mylar foil was pressed on each side of the mold and kept in place with a clamp. Each specimen was light-cured on both sides for 20 s. After demolding excess material was carefully removed.

Measurement of Martens hardness

Martens hardness was measured with a universal testing machine (ZHU 2.5, Zwick/Roell, Ulm, Germany), using a Vickers indenter. A load of 10 N was applied. The crosshead speed was set to 5 N/min. Each hardness value was calculated as mean of three indentations. Furthermore, plastic and elastic indentation work was registered.

Measurement of indirect tensile strength

To measure indirect tensile strength, specimens were loaded in a universal testing machine (Z020, Zwick/Roell, Ulm, Germany) perpendicular to the cylinder axis until fracture. The crosshead speed was set to 1 mm/min. The indirect tensile strength was calculated according to the following equation:

$$ \upsigma = 2\mathrm{F}/\uppi \mathrm{d}\mathrm{h} $$

F = load at fracture; d = diameter of the specimen; h = height of the specimen

Endpoint of post-polymerization

To identify the endpoint of post-polymerization after light-curing, specimens for hardness measurement were prepared (n = 6). The specimens were removed from the mold immediately after light-curing and Martens hardness was measured. Subsequently the specimens were stored in deionized water at 37 °C. Martens hardness was measured on all specimens after 1, 6, 12, 24, 48 and 96 h storage time.

Artificial aging

From each cement 2 sets of specimens for Martens hardness measurements were prepared. On all specimens hardness was measured immediately after light-curing. Subsequently, the specimens were stored in water for 1 day at 37 °C to allow complete polymerization and hardness was measured again prior to aging (baseline value).

Indirect tensile strength after light-curing was measured with 1 set of specimens. All further sets of specimens were stored in deionized water at 37 °C for 1 day to allow complete polymerization. Indirect tensile strength after 1 day of water storage was measured with 1 set of specimens (baseline value).

For each cement, 1 set of specimens for Martens hardness measurements and 1 set for indirect tensile strength tests were stored in deionized water at 37 °C, 1 set of specimens for Martens hardness measurements and 1 set for indirect tensile strength tests were thermo-cycled. For thermal cycling a customized device was used. The specimens were immersed alternately in water baths of 5 °C and 55 °C, using a sieve for storage and transportation. The cycle duration was 1 min with a dwell time of 28 s in each bath and a transfer time of 2 s between the baths.

Hardness was measured after 1, 4, 9, and 16 days of storage on the same specimens. Indirect tensile strength was measured after 16 days of aging. For PDC an additional value of indirect tensile strength after 4 days of thermal cycling was obtained with one more set of specimens.

Statistics

All groups were tested for normal distribution with Shapiro-Wilk test. The groups were normal distributed and therefore compared using one-way analysis of variance (ANOVA, SPSS, SPSS Inc., Chicago, IL, US). All results with a P-value < 0.05 were considered as statistically significantly different.

Results

Endpoint of post-polymerization

In the first 24 h of water storage an increase in hardness was found in all 4 cements. Then hardness remained constant (Fig. 1).

Fig. 1
figure 1

Martens hardness as a function of time during post-polymerization

Effect of aging

Short-term water storage for 16 days slightly affected Martens hardness (Fig. 2a). After thermal cycling the effect was more pronounced and already evident after 1 day of aging (Fig. 2b).

Fig. 2
figure 2

Martens hardness as a function of time during a water storage b thermal cycling

Figure 3a and b are provided to compare the means and standard deviations of Martens hardness and indirect tensile strength, respectively, after light-curing, at baseline (1 day water storage at 37 °C), after 16 days aging by water storage at 37 °C and after 16 days aging by thermal cycling.

Fig. 3
figure 3

Means and standard deviations of a Martens hardness and b indirect tensile strength after light-curing (LC), at baseline, after 16 days of water storage (WS) and after 16 days of thermal cycling (TC)

In all cases baseline values for hardness and indirect tensile strength were significantly higher than after light-curing (p < 0.001). After water storage for 16 days hardness was significantly reduced for VL2 (p = 0.008), RUN (p = 0.006), DCM (p = 0.022) and PDC (p < 0.001) while indirect tensile strength of all cements were not significantly affected (p > 0.05). Thermal cycling for 16 days in all cases significantly reduced hardness and indirect tensile strength in comparison to the respective baseline values (p < 0.01).

The ratio of the plastic and elastic indentation work significantly dropped after complete polymerization, compared to the situation directly after light-curing, but no further change was observed during aging (Fig. 4).

Fig. 4
figure 4

Ratio of plastic and elastic indentation work

Correlation between Martens hardness and indirect tensile strength

Although the patterns of Martens hardness (Fig. 3a) and indirect tensile strength (Fig. 3b) are similar, no general correlation between both values was found. However, a strong linear correlation was observed for each particular material (Fig. 5). In addition, when plotting the relative change of Martens hardness (absolute decrease of Martens hardness [ΔHM] divided by the baseline value [HM0]) against the relative change of indirect tensile strength (absolute decrease of indirect tensile strength [Δσ] divided by the baseline value [σ0]) a strong linear correlation is obvious with all 4 regression curves running through the origin (Fig. 6).

Fig. 5
figure 5

Correlation between Martens hardness and indirect tensile strength for each cement

Fig. 6
figure 6

Correlation between relative change of Martens hardness and relative change of indirect tensile strength for each cement

Discussion

Endpoint of post-polymerization

The obtained results when following the polymerization process after light-curing suggest that hardness measurements correlate with the degree of polymerization of the cements. To the knowledge of the authors the use of Martens hardness measurements in order to characterize the progress of polymerization is not published yet. However, the process of polymerization of resin cements was previously characterized using Knoop-hardness [30, 31]. Vickers [32, 33] and Knoop hardness [34] have been applied to test the degree of polymerization [32, 34] and polymerization shrinkage [33]. All 4 tested cements reached a constant level of hardness after 1 day of storage time, indicating that the polymerization was substantially finished. It was reasoned from the results that in a laboratory test setup a 1 day water storage at 37 °C is recommended for all 4 cements to allow complete polymerization.

Artificial aging

In the present study the effect of short-term water storage at 37 °C on indirect tensile strength is not as effective as observed in a previous investigation, where 16 days of water storage significantly reduced the indirect tensile strength of a different cement [22]. Therefore, the immersion time in water over 16 days was too short to produce a measurable effect with Martens hardness.

In the present as well as in a previous study [22] thermal cycling revealed to be more effective. However, published results in general are not consistent. That may be explained to some extent by the various methods, which differ in the duration for one cycle and the temperature or the storing medium. Some authors determined a slight decrease [26, 29] while others found a slight increase in strength [27,28,29].

A specific correlation between Martens hardness and indirect tensile strength for each cement was observed in the present study. A study with a similar test design, which evaluated Vickers hardness and indirect tensile strength was published by Medeiros et al. [23]. Artificial aging of one light-cured composite resin restorative material was carried out by storing the specimens in alcohol, acetic acid, or propionic acid. Regression between mean values of Vickers hardness and indirect tensile strength reveal a linear correlation. Aguiar et al. [25] did not find any correlation between hardness and indirect tensile strength when investigating several different materials. Both results correspond to the present findings. For one single material a correlation between hardness and indirect tensile strength is given, but when comparing multiple materials, no general correlation can be found.

The most important finding in the present study is the fact that the relative variations of Martens hardness and indirect tensile strength following aging reveal a very strong linear correlation specific for each cement, with the regression line running exactly through the point of origin. However, a comparison between different materials must be performed carefully.

Aging in water resulted in significant differences between Martens hardness but not for indirect tensile strength values for all cements when compared to baseline. Therefore measuring Martens hardness can be considered a more sensitive test method for evaluating aging procedures of resin composite cements than indirect tensile strength test.

The invariable ratio between plastic and elastic indentation work during aging indicates that no structural changes in the materials such as an embrittlement occurred which could have changed elasticity or plasticity.

Limitations of the study

It is proposed that 10,000 cycles may represent 1 year of service [18]. In the present study thermal cycling was performed over 16 days indicating more than 2 years of service. For water storage at 37 °C an immersion time of 16 days was too short to induce same degradations as they were found for specimens that were aged by thermal cycling. Martens hardness and indirect tensile strength measurements seem to be suitable methods to detect surface degradations induced by aging. However, further investigations are required to test the change in depth of the specimens over time.

Conclusions

Within the limitations of this study it can be concluded that:

  • For artificial aging of resin composite cements thermal cycling (5 °C/55 °C) is more effective than water storage at 37 °C.

  • Degradation of resin composite cements after artificial aging may be detected by Martens hardness measurements.

  • The relative changes in Martens hardness and indirect tensile strength induced by aging are strongly correlated within one material.

Abbreviations

DCM:

DuoCem

HM:

Martens hardness

PDC:

PermaFlo DC

RUN:

RelyX Unicem 2 Automix

VL2:

Variolink II

References

  1. Fasbinder DJ. Clinical performance of chairside CAD/CAM restorations. J Am Dent Assoc. 2006;137(Suppl):22–31.

    Article  Google Scholar 

  2. Kelly JR, Nishimura I, Campbell SD. Ceramics in dentistry: historical roots and current perspectives. J Prosthet Dent. 1996;75:18–32.

    Article  CAS  PubMed  Google Scholar 

  3. Reiss B, Walther W. Clinical long-term results and 10-year Kaplan-Meier analysis of Cerec restorations. Int J Comput Dent. 2000;3:9–23.

    CAS  PubMed  Google Scholar 

  4. Land MF, Hopp CD. Survival rates of all-ceramic systems differ by clinical indication and fabrication method. J Evid Based Dent Pract. 2010;10:37–8.

    Article  PubMed  Google Scholar 

  5. Mehl A, Hickel R. Current state of development and perspectives of machine-based production methods for dental restorations. Int J Comput Dent. 1999;2:9–35.

    CAS  PubMed  Google Scholar 

  6. Wiedhahn K, Kerschbaum T, Fasbinder DF. Clinical long-term results with 617 Cerec veneers: a nine-year report. Int J Comput Dent. 2005;8:233–46.

    CAS  PubMed  Google Scholar 

  7. Steeger B. Survival analysis and clinical follow-up examination of all-ceramic single crowns. Int J Comput Dent. 2010;13:101–19.

    PubMed  Google Scholar 

  8. Pjetursson BE, Sailer I, Zwahlen M, Hämmerle CH. systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part I: Single crowns. Clin Oral Implants Res. 2007;18 Suppl 3:73–85.

    Article  PubMed  Google Scholar 

  9. Bindl A, Lüthy H, Mörmann WH. Strength and fracture pattern of monolithic CAD/CAM-generated posterior crowns. Dent Mater. 2006;22:29–36.

    Article  CAS  PubMed  Google Scholar 

  10. Kvam K. Fracture toughness determination of ceramic and resin-based dental composites. Biomaterials. 1992;13:101–4.

    Article  CAS  PubMed  Google Scholar 

  11. Schmidt KK, Chiayabutr Y, Phillips KM, Kois JC. Influence of preparation design and existing condition of tooth structure on load to failure of ceramic laminate veneers. J Prosthet Dent. 2011;105:374–82.

    Article  PubMed  Google Scholar 

  12. Guess PC, Schultheis S, Wolkewitz M, Zhang Y, Strub JR. Influence of preparation design and ceramic thicknesses on fracture resistance and failure modes of premolar partial coverage restorations. J Prosthet Dent. 2013;110:264–73.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  13. Holderegger C, Sailer I, Schuhmacher C, Schläpfer R, Hämmerle CH, Fischer J. Shear bond strength of resin cements to human dentin. Dent Mater. 2008;24:944–50.

    Article  CAS  PubMed  Google Scholar 

  14. Addison O, Sodhi A, Fleming GJ. Seating load parameters impact on dental ceramic reinforcement conferred by cementation with resin-cements. Dent Mater. 2010;26:915–21.

    Article  CAS  PubMed  Google Scholar 

  15. Abedin F, Ye Q, Parthasarathy R, Misra A, Spencer P. Polymerization behavior of hydrophilic-rich phase of dentin adhesive. J Dent Res. 2015;94:500–7.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  16. Hitz T, Stawarczyk B, Fischer J, Hämmerle CH, Sailer I. Are self-adhesive resin cements a valid alternative to conventional resin cements? A laboratory study of the long-term bond strength. Dent Mater. 2012;28:1183–90.

    Article  CAS  PubMed  Google Scholar 

  17. Gal M, Darvell B. Thermal cycling procedures for laboratory testing of dental restorations. J Dent. 1999;27:89–99.

    Article  Google Scholar 

  18. Morresi AL, D'Amario M, Capogreco M, Gatto R, Marzo G, D'Arcangelo C, Monaco A. Thermal cycling for restorative materials: does a standardized protocol exist in laboratory testing? A literature review. J Mech Behav Biomed Mater. 2014;29:295–308.

    Article  CAS  PubMed  Google Scholar 

  19. Chadwick RG. Thermocycling--the effects upon the compressive strength and abrasion resistance of three composite resins. J Oral Rehabil. 1994;21:533–43.

    Article  CAS  PubMed  Google Scholar 

  20. Hirabayashi S, Nomoto R, Harashima I, Hirasawa T. The surface degradation of various light-cured composite resins by thermal cycling. Shika Zairyo Kikai. 1990;9:53–64.

    CAS  PubMed  Google Scholar 

  21. Drummond JL. Degradation, fatigue, and failure of resin dental composite materials. J Dent Res. 2008;87:710–19.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  22. Blumer L, Schmidli F, Weiger R, Fischer J. A systematic approach to standardize artificial aging of resin composite cements. Dent Mater. 2015;31:855–63.

    Article  CAS  PubMed  Google Scholar 

  23. Medeiros IS, Gomes MN, Loguercio AD, Filho LE. Diametral tensile strength and Vickers hardness of a composite after storage in different solutions. J Oral Sci. 2007;49:61–6.

    Article  PubMed  Google Scholar 

  24. Aguiar FH, Braceiro AT, Ambrosano GM, Lovadino JR. Hardness and diametral tensile strength of a hybrid composite resin polymerized with different modes and immersed in ethanol or distilled water media. Dent Mater. 2005;21:1098–103.

    Article  CAS  PubMed  Google Scholar 

  25. Brosh T, Ganor Y, Belov I, Pilo R. Analysis of strength properties of light-cured resin composites. Dent Mater. 1999;15:174–9.

    Article  CAS  PubMed  Google Scholar 

  26. Fischer J, Roeske S, Stawarczyk B, Hämmerle CH. Investigations in the correlation between Martens hardness and flexural strength of composite resin restorative materials. Dent Mater J. 2010;29:188–92.

    Article  CAS  PubMed  Google Scholar 

  27. Borba M, Della Bona Á, Cecchetti D. Flexural strength and hardness of direct and indirect composites. Braz Oral Res. 2009;23:5–10.

    Article  PubMed  Google Scholar 

  28. Hahnel S, Henrich A, Bürgers R, Handel G, Rosentritt M. Investigation of mechanical properties of modern dental composites after artificial aging for one year. Oper Dent. 2010;35:412–9.

    Article  PubMed  Google Scholar 

  29. dos Reis AC, de Castro DT, Schiavon MA, da Silva LJ, Agnelli JA. Microstructure and mechanical properties of composite resins subjected to accelerated artificial aging. Braz Dent J. 2013;24:599–604.

    Article  PubMed  Google Scholar 

  30. Rasetto FH, Driscoll CF, von Fraunhofer JA. Effect of light source and time on the polymerization of resin cement through ceramic veneers. J Prosthodont. 2001;10:133–9.

    Article  CAS  PubMed  Google Scholar 

  31. Santos Jr GC, El-Mowafy O, Rubo JH, Santos MJ. Hardening of dual-cure resin cements and a resin composite restorative cured with QTH and LED curing units. J Can Dent Assoc. 2004;70:323–8.

    PubMed  Google Scholar 

  32. Gregor L, Bouillaguet S, Onisor I, Ardu S, Krejci I, Rocca GT. Microhardness of light- and dual-polymerizable luting resins polymerized through 7.5-mm-thick endocrowns. J Prosthet Dent. 2014;112:942–8.

    Article  CAS  PubMed  Google Scholar 

  33. Frassetto A, Navarra CO, Marchesi G, Turco G, Di Lenarda R, Breschi L, Ferracane JL, Cadenaro M. Kinetics of polymerization and contraction stress development in self-adhesive resin cements. Dent Mater. 2012;28:1032–9.

    Article  CAS  PubMed  Google Scholar 

  34. Yoshida K, Meng X. Microhardness of dual-polymerizing resin cements and foundation composite resins for luting fiber-reinforced posts. J Prosthet Dent. 2014;111:505–11.

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgements

The materials were kindly provided by VITA Zahnfabrik, Bad Säckingen, Germany.

Funding

No funding.

Availability of data and materials

All references are available at pubmed.com

Authors’ contributions

SB collected the data and wrote the manuscript. NR proofread the manuscript and helped with the interpretation of the data and the statistical analysis. JF designed the concept, interpreted the data and proofread the manuscript. All authors read and approved the final manuscript.

Competing interests

The authors declare that they have no competing interests.

Consent for publication

Not applicable.

Ethics approval and consent to participate

Not applicable.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Nadja Rohr.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Bürgin, S., Rohr, N. & Fischer, J. Assessing degradation of composite resin cements during artificial aging by Martens hardness. Head Face Med 13, 9 (2017). https://doi.org/10.1186/s13005-017-0142-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13005-017-0142-4

Keywords