From: Micro-morphologic changes around biophysically-stimulated titanium implants in ovariectomized rats
p | Group | Mean | Std. Deviation | Std. Error | 95% Confidence interval for mean | Minimum | Maximum | ||
---|---|---|---|---|---|---|---|---|---|
Lower Bound | Upper Bound | ||||||||
VOI-1 | 0.003 | Control | 2.027 | 0.830 | 0.262 | 1.432 | 2.621 | 1.305 | 3.884 |
MECHVIB | 3.170 | 0.734 | 0.244 | 2.615 | 3.744 | 1.535 | 4.181 | ||
PEMF | 2.09 | 0.636 | 0.201 | 1.642 | 2.552 | 1.083 | 3.162 | ||
VOI-2 | 0.025 | Control | 2.214 | 0.786 | 0.248 | 1.651 | 2.777 | 1.413 | 3.846 |
MECHVIB | 3.014 | 0.716 | 0.226 | 2.502 | 3.527 | 1.730 | 3.622 | ||
PEMF | 2.170 | 0.676 | 0.213 | 1.687 | 2.654 | 1.176 | 3.381 | ||
VOI-3 | 0.006 | Control | 2.051 | 0.576 | 0.182 | 1.638 | 2.463 | 1.479 | 3.259 |
MECHVIB | 2.803 | 0.406 | 0.128 | 2.512 | 3.094 | 1.826 | 3.234 | ||
PEMF | 2.166 | 0.527 | 0.166 | 1.788 | 2.543 | 1.258 | 2.996 |