Skip to main content

Table 6 Changes in the detection rates of mucosal thickening according to the extent of mucosal thickening in the maxillary sinus on panoramic radiographs in 61 patients

From: The significance of cone beam computed tomography for the visualization of anatomical variations and lesions in the maxillary sinus for patients hoping to have dental implant-supported maxillary restorations in a private dental office in Japan

Widths of mucosal thickening in maxillary sinus on CBCT Detection rate of Panoramic radiographs (Frequency)
0 < <=1 mm 0% (0/1)
1 < <=2 mm 0% (0/8)
2 < <=3 mm 30% (3/10)
3 < <=4 mm 33% (2/6)
4 < <=5 mm 40% (2/5)
5 < <=6 mm 20% (1/5)
6 < <=7 mm 50% (1/2)
7 < <=8 mm 25% (1/4)
8 < <=9 mm -
9 < <=10 mm 0% (0/4)
10 < mm 67% (4/6)
  1. CBCT: Cone beam computed tomography.