Skip to main content

Table 1 The muscular force applied in the FE models according to experimental data by Korioth and Koolstra

From: Biomechanical evaluation of type p condylar head osteosynthesis using conventional small-fragment screws reinforced by a patient specific two-component plate

Side

Direction

Muscular force (N)

SM

DM

ILP

MP

AT

PT

 

Force (maximum loading)

272.8

69.8

112.8

240

308

222

RS

Fx

−56.56

−38.19

71

116.6

46.4

44.4

Fy

−114.2

−25

−85

− 189.67

−14.6

−192.4

Fz

240.9

53

19

89.56

305.5

103.6

LS

Fx

56.56

38.19

− 71

− 116.6

−46.4

44.4

Fy

−114.2

−25

−85

−189.67

14.6

192.4

Fz

240.9

53

19

89.56

305.5

103.6

 

Force (normal loading)

68.2

17.45

28.2

60

77

55.2

Rs

Fx

−14.14

−9,5

17.75

29.16

11.61

11.1

Fy

−28.55

−6.25

−21.37

−22.39

−3.6

−48.1

Fz

60.23

13.25

4.93

47.41

76.38

25.9

LS

Fx

14.14

9.5

−17.75

−29.16

−11.61

11.1

Fy

−28.55

−6.25

−21.37

−22.39

3.6

48.1

Fz

60.23

13.25

4.93

47.41

76.38

25.9