Skip to main content

Table 1 Maximum displacement values and stress observed in the three models analyzed.

From: Applied mechanics of the Puricelli osteotomy: a linear elastic analysis with the finite element method

Mandible model

Maximum displacement value (mm)

Maximum von Mises stress (MPa)

No split

0.107

1.31

Obwegeser-Dal Pont split

0.127

1.80

Puricelli split

0.118

1.22