Skip to main content

Table 4 Descriptive statistics of trabecular-separation (mm) around implants of test and control groups (n = 15).

From: Micro-morphologic changes around biophysically-stimulated titanium implants in ovariectomized rats

 

p

Group

Mean

Std. Deviation

Std. Error

95% Confidence interval for mean

Minimum

Maximum

      

Lower Bound

Upper Bound

  

VOI-1

0.161

Control

0.546

0.254

0.008

0.363

0.728

0.253

0.938

  

MECHVIB

0.530

0.221

0.007

0.372

0.688

0.106

0.821

  

PEMF

0.718

0.229

0.007

0.554

0.882

0.402

1.065

VOI-2

0.134

Control

0.572

0.249

0.007

0.393

0.750

0.303

0.918

  

MECHVIB

0.521

0.204

0.006

0.375

0.668

0.122

0.803

  

PEMF

0.725

0.225

0.007

0.563

0.886

0.412

1.046

VOI-3

0.216

Control

0.573

0.204

0.006

0.426

0.720

0.365

0.861

  

MECHVIB

0.474

0.168

0.005

0.354

0.595

0.190

0.735

  

PEMF

0.634

0.222

0.007

0.475

0.793

0.334

0.950