Table 3 Overview on CTDIVol and DLP values for each scanning protocol for preoperative assessment

From: Dose development in sinonasal imaging over the last decade – a retrospective patient study

 

CTDIVol

 

DLP

Scanning protocol

Mean

(mGy)

Reduction in % compared to DS 64 / FBP

 

Mean ± Std. Dev.

(mGy x cm)

Reduction in % compared to DS 64 / FBP

DS 64 / FBP

4.6

-

 

65

±

10

-

DS 64 / 1st Gen.

4.6

0

 

67

±

25

+ 3

DS 64 / 2nd Gen.

4.6

+ 1

 

69

±

17

+ 7

SS 128 / FBP

2.6

43

 

35

±

4

46

SS 128 / 2nd Gen.

2.2

53

 

33

±

8

49

DS 192 / 3rd Gen. + ATCM

9.2

+ 102

 

169

±

57

+ 162

DS 192 / 3rd Gen. - ATCM

2.1

54

 

41

±

14

36

DS 192 / 3rd Gen. 2022

2.1

54

 

43

±

22

33

  1. Mean value (± standard deviation) of CTDIVol and DLP values of protocols used for preoperative assessment in the past 12 years. Additionally, the dose reduction in percent per scan protocol compared the DS 64 / FBP protocol is shown for the CTDIVol and DLP values. ATCM = automatic tube current modulation, CBCT = cone beam CT, CT = computed tomography, CTDIVol = computed tomography dose index, DLP = dose length product, FBP = filtered back projection, Gen. = generation.